Temperature and humidity transmitters T3413(D) and T3417(D) with RS232 and RS485 outputs. — Sensors T3413(D) and T3417(D)
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
Temperature and humidity converters with RS232 and RS485 outputs. Housed in a reliable wear-resistant case. There is an option to program the output signal. The large two-line LCD display is designed for simultaneous display of two parameters. Intended for installation in a ventilation duct.
The sensors are capable of meeting the highest requirements for use in ventilation and air conditioning systems. They are resistant to contamination and provide maintenance-free operation and excellent long-term stability.
Recently, temperature and humidity levels have been considered as the most important parameters responsible for indoor climate quality. Especially in buildings and rooms with large gatherings of people, such as conference halls, hospitals, schools, cinemas, theaters, and wellness centers.
With the help of such sensors, engineers, environmental experts, and healthcare specialists can optimize ventilation to create a comfortable and "Healthy" indoor climate.
ATTENTION, the device is currently discontinued.
- Specifications
- Overall Drawing
- Electrical diagram
- Applications
|
Sensors |
T3413(D) |
T3417(D) |
||
|
Output signal |
RS485 |
|||
|
Temperature |
Range |
-30 to +125°C |
||
|
Accuracy |
± 0.4°C |
|||
|
Relative Humidity (at 5-95% RH and 23°C) |
Range |
0 to 100 % RH |
||
|
Accuracy |
± 2.5%RH |
|||
|
Accuracy and range of dew point temperature measurement |
±1.5°C at ambient temp. T<25°C and RH >30% |
|||
|
Accuracy and range of absolute humidity measurement |
±1.5 g/m3 at ambient temp. T < 25°C |
|||
|
Accuracy and range of specific humidity measurement |
±2 g/kg at ambient temp. T < 35°C |
|||
|
Accuracy and range of specific enthalpy measurement |
±3 kJ/kg at ambient temp. T < 25°C |
|||
|
Accuracy and range of mixture component ratio measurement |
±2 g/kg at ambient temp. T < 35°C |
|||
|
Power supply voltage |
9 - 30 Vdc |
|||
|
Sensor / external sensor protection class |
IP65/IP40 |
|||
|
Material of the sensor immersion part |
Stainless steel 1.4301 |
|||
|
Operating temperature range of the sensor |
-30 to +80°C |
|||
|
Operating temperature range of the external sensor |
-30 to +1250C |
|||
|
Operating humidity range (without condensation) |
0 to 100 % RH |
|||
|
Storage temperature range |
-30 to +80°C |
|||
|
Recommended calibration interval |
1 year |
|||
|
Dimensions / Weight |
88.5 x 95 x 195 mm (W x H x D), rod length 150 mm / 225 g |
88.5 x 94 x 745 mm (W x H x D), rod length 700 mm / 580 g |
||
|
Warranty |
3 years |
|||