New dew point sensors with digital and analog outputs — FA 510 / FA 515
Specification FA 510 / FA 515 (sensor for refrigerated dryers)
Specification FA 510 / FA 515 (sensor for adsorption dryers)
Questionnaire FA 510 / FA 515
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
Dew point sensors FA 510 and FA 515 are devices for measuring the dew point temperature in compressed air environments. The devices can perform measurements even in extremely dry air (down to -80°CTd). The standard application of the sensor is measuring the dew point during gas drying using both adsorption and refrigeration dryers. The device can operate at pressures up to 50 bar, and a special version of the device is also available for measurements at pressures up to 350 bar. A measuring chamber equipped with a quick-release connection is available as an accessory. With optional software, it is possible to configure the analog output to display values in % RH, °Ctd, g/m3, mg/m3, ppm V/V.
Compared to previous versions of the sensors (FA 410 and FA 510), the sensors are equipped with more advanced sensitive elements and electronic components. In particular, improvements were made to the temperature compensation calculation algorithm. This has led to increased accuracy and signal resolution of the sensors. The sensitive element of the devices is insensitive to condensate and, thanks to the sintered steel cap, is protected from direct contact with dirt particles.
Sensor Features:
- Digital Modbus output
- Analog output 4...20 mA (2-wire or 3-wire connection)
- High long-term stability values
- Insensitive to condensate
- Fast response time
- Measurement range down to -80...20°Ctd
- Operating pressure up to 350 bar (special version)
- Specifications
- Overall Drawing
- Connection diagram
- Applications
| Technical Specifications FA 510 / FA 515 | |
| Measurement Ranges | -110...+20 °Ctd -80...+20 °Ctd -40...+30 °Ctd -20...+50 °Ctd |
| Accuracy | ±1°C at 20...-20°Ctd ±2°C at -20...-50°Ctd ±3°C at -50...-80°Ctd |
| Operating Pressure | -1...50 bar special version up to 350 bar |
| Power Supply | 24 VDC (16...30 VDC) |
| Protection Class | IP 65 |
| EMC | according to DIN EN 61326 |
| Operating Temperature | -20...+70 °C |
| Electrical Connection | 2 x M12, 5-pin |
| PC Interface | Modbus-RTU Interface (RS 485) |
| Analog Output | 4...20 mA = -80...20°Ctd 4...20 mA = -20...50°Ctd FA 510: 3-wire connection FA 515: 2-wire connection |
| Analog Output Load | <500 Ohm |
| Process Connection | G 1/2“ Optional: UNF 5/8“ NPT 1/2“ |
| Dimensions | Ø 30 mm, length 130 mm |
| Settings via Software |
Units of measurement: % RH, °Ctd, g/m³, mg/m³, ppm V/V; |


|
Contact Number |
Contact 1 |
Contact 2 |
Contact 3 |
Contact 4 |
Contact 5 |
|
Cable Color |
brown |
white |
blue |
black |
gray |
|
Contact Purpose |
Power supply plus 24 VDC |
Modbus A (+) |
Power supply minus |
Modbus B (-) |
Analog output 4...20 mA |
|
Contact Purpose |
Power supply plus 24 VDC |
Modbus A (+)* |
Power supply minus |
Modbus B (-)* |
Not connected |
*Not used when connected via 2-wire scheme.