Russian manufacturer
of instrumentation and control equipment

Working hours

  • Monday
    09:00-18:00
  • Tuesday
    09:00-18:00
  • Wednesday
    09:00-18:00
  • Thursday
    09:00-18:00
  • Friday
    09:00-18:00
  • Saturday
    Closed
  • Sunday
    Closed
EN
RU EN

8 (800) 777 18 50

Request a quote
  • Monday
    09:00-18:00
  • Tuesday
    09:00-18:00
  • Wednesday
    09:00-18:00
  • Thursday
    09:00-18:00
  • Friday
    09:00-18:00
  • Saturday
    Closed
  • Sunday
    Closed
EN
RU EN
Request a quote

Dew point sensor in a durable die-cast aluminum housing — FA 550

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The FA 550 sensor is the ideal solution for measuring dew point temperature outdoors or in harsh industrial conditions. It provides reliable dew point control with long-term stability in industrial applications.

When the FA 550 sensor is installed in compressed air systems, the dew point under pressure (pressure dew point) up to 50 bar (up to 500 bar in special versions) is measured directly. When the sensor is installed in atmospheric conditions (at ambient pressure) or in the air outlet zone (at atmospheric pressure) from compressor units, the atmospheric dew point is measured.

Special Advantages

  • Robust sealed die-cast aluminum housing, protection class IP 67
  • Signal relay threshold value adjustable via buttons on the display (max. 60 V DC, 0.5 A)
  • Analog output 4...20 mA
  • Optional: two analog outputs 4…20 mA, e.g., for dew point temperature and ambient temperature
  • Extremely high long-term stability
  • Fast response time
  • Operating pressure up to 500 bar (optional)
  • New: Modbus RTU interface
  • New: Ethernet interface (optional)
  • New: higher signal resolution thanks to improved electronics
  • New: on-site sensor diagnostics using portable devices or CS Service Software
  • Via Modbus, the following values are available: dew point temperature under pressure [°C dp], temperature [°C], relative humidity [% RH], absolute humidity [g/m³], volumetric moisture content [ppm V/V], saturated vapor pressure [hPa], atmospheric dew point [atm. °C dp]

Applications

  • Measurement of compressed air dew point temperature after adsorption / membrane / refrigeration dryers
  • Measurement of residual moisture / dew point of various gases such as oxygen, nitrogen, argon, hydrogen, natural gas, biogas, etc.
  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications

Technical Specifications

Measurement Range -80...+20 °C t.r., -60...+30 °C t.r.,
-20...+50 °C t.r.,
-0...100% RH
Accuracy ± 1°C at +50...-20°C t.r.
± 2°C at -20...-50°C t.r.
± 3°C at -50...-80°C t.r.
Measurement Range: -1...50 bar
special version up to 500 bar
Power Supply 24 V DC (18...30 V DC)
Protection Class IP 67
EMC according to DIN EN 61326-1
Operating Temperature -20...+70°C (optimal 0...+50°C)
Outputs Standard:
Modbus RTU, 4...20 mA,
active (without galvanic isolation), signal relay (max. 48 V DC, 0.5 A)
Load < 500 Ohm
Material Housing: die-cast aluminum
Probe: stainless steel, 1.4571
Connection Thread G 1/2“, optionally 5/8“ UNF

Standard version with one analog output (not galvanically isolated)
Version with two galvanically isolated analog outputs
Version with MBus option

Send request

Request a callback

Information sent successfully

Благодарим за обращение.
Ваша заявка будет рассмотрена в рабочее время:
Пн-Пт с 9 до 18 по московскому времени.