Hygrometer and thermometer with data logger function for compressed air measurements up to 2.5 MPa. — S3121P
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
Humidity and temperature meter for compressed air with data logger function is designed to measure and record temperature and humidity in an air environment with pressure up to 2.5 MPa. The device is powered by a replaceable internal power source. Measured values are stored at set time intervals in internal non-volatile memory and displayed on a screen that shows two measured parameters simultaneously. Control and configuration of the logger are carried out via a computer with password protection. Data transfer to a PC is possible via USB, RS232, GSM, or Ethernet.
ATTENTION, the device is currently discontinued.
- Specifications
- Applications
|
Sensor |
S3121 |
|
Measured values |
Relative humidity + Temperature |
|
Measured medium |
Compressed moist air with pressure up to 2.5 MPa |
|
Operating temperature range of the device |
from -30 to +105°C |
|
LCD display |
Yes |
|
Measured temperature and humidity range of the probe |
from -30 to +105°C, from 0 to 100%RH |
|
Temperature measurement accuracy |
±0.4°C from -30 to +80°C, ±0.5°C above 80°C |
|
Humidity measurement accuracy |
±2.5%RH from 5 to 95%RH at 23°C |
|
Dew point measurement range |
From -60 to +80°C |
|
Dew point temperature measurement accuracy |
±1.5°C for dew point temperature from +10°C and above at ambient temperature +25°C |
|
Dew point temperature measurement accuracy |
±2.0°C for dew point temperature from 0°C at ambient temperature +25°C |
|
Dew point temperature measurement accuracy |
±3.0°C for dew point temperature from -10°C at ambient temperature +25°C |
|
Dew point temperature measurement accuracy |
±6.0°C for dew point temperature from -20°C at ambient temperature +25°C |
|
Measurement step |
0.1°C, 0.1%RH |
|
Data recording intervals |
From 10 sec. to 24 hours (from 1 min. to 24 hours in power saving mode) |
|
Display and alarm update frequency |
Every 10 seconds (every minute in power saving mode) |
|
Total memory capacity |
32,000 temperature and humidity values in non-cyclic recording mode |
|
Recording modes |
Non-cyclic – data recording stops after memory is full. Cyclic – after memory is full, the oldest value is overwritten with the new one. |
|
Dimensions (without probe) |
93x64x29 mm |
|
Power supply |
3.6 V lithium battery, size AA |
|
Battery life in power saving mode (updates once per minute) |
6 years |
|
Battery life in fast mode (updates every 10 sec) |
2.5 years |
|
Autonomous operation time in continuous online mode with 1-minute interval |
Reduced to 70% of fast mode |
|
Autonomous operation time in continuous online mode with 10-second interval |
1 year |
|
Protection class |
IP67 – Protected against short-term immersion in water. RH+T sensor protected by a 0.025 mm stainless steel micron mesh with IP40 |
|
External probe cable length |
1, 2 or 4 meters (optional) |
|
Weight |
115 g (with battery, without probe) |
|
Warranty |
3 years |