Float Level Gauge — IZMERKON DI/P-26
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The operating principle of the IZMERKON DI/P-26 float level meter for liquids is based on the buoyant force effect of the liquid. Using a magnetic float connected to a magnet located in the transmitter, the liquid level is converted into a standard industrial signal of 4...20 mA.
The device features a simple design, ease of installation, the ability to directly transmit liquid level data, immunity to medium density influence, no leaks or contamination, making the level meter ideal for use in the food, medical, printing, dyeing, chemical industries, energy sector, and other fields.
The IZMERKON DI/P-26 level meter series includes both standard sensor versions for multi-industry applications and versions designed for specific conditions of various industries, which can be custom-made according to user requirements.
Features and Advantages
- Measurement range: depth L ≤ 2 m (adjustable value)
- Operating pressure: ≤1 MPa
- Electrical connection: M20×1.5 (adjustable value)
- Process connection: M42×1.5 (adjustable value)
- Accuracy: ±10 mm
- Output signal: 4...20 mA (2-wire connection)
- Float dimensions: 55×45×15
- Measured medium: media compatible with stainless steel 304 or 316L
- Zero adjustment: direct adjustment via contact switching on the printed circuit board
- Specifications
- Overall dimensions drawing
- Connection diagram
- Applications
Output Signal and Power Supply Voltage |
||
| Current (2-wire) | 4...20 mA | 12...30 V (DC) |
Operating Characteristics |
|
| Protection Rating | IP68 (probe) |
| Atmospheric Pressure | 86...106 kPa |
| Allowable Vibration | 10g (at 10...2000 Hz) |
| Shock Resistance | 100g/11ms |
| Service Life | >10 million load cycles (within measurement range) |
Environmental Conditions |
|
| Medium Temperature | -30...70°C |
| Ambient Temperature | -40...70°C |
| Storage Temperature | -40...70°C |
Note: freezing of the measured medium may cause irreversible damage to the device.
Unit of measurement: mm
.jpg)
.jpg)
Drawings refer to the standard version of the device. To obtain drawings for a specific version, please contact the supplier.
Diagram |
Contacts |
Purpose (2-wire) |
![]() |
1 | PE |
| 2 | / | |
| 3 | Iout | |
| 4 | Vcc |