Fuel level gauge with CAN interface and 0-10 V analog output — E2706
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The E2706 model with CAN interface and analog output (0-10 V) is the latest representative of the Evikon E2700 digital sensor line, designed for high-precision measurement of fuel level in automotive and stationary tanks. Applications include active driving systems, vehicle tracking, and control. Stability, accuracy, and reliability of measurements are achieved thanks to the high precision of capacitive measurement technology with digital signal processing and the high durability of the sensor design.
Key features:
- Convenient reliable design
- Ease of installation
- Possibility to shorten the rod
- CAN interface with J1939 protocol
- Analog output 0-10 V
The sensor resolution is less than 0.1% of the measurement scale, in most cases 0.07 mm. Thus, high measurement accuracy is ensured even in flat tanks. Thanks to two adjustable digital integrating filters, short-term fuel level fluctuations do not affect the sensor readings. The built-in 32-point calibration system ensures a high degree of linearity of readings in user-selected volume measurement units.
The E2706 sensor is designed to provide maximum reliability and optimal operating characteristics. The sensor rod is made of a special lightweight alloy characterized by high strength and corrosion resistance. A vertical slot in the rod prevents clogging with fuel residues, facilitates cleaning, and reduces response time compared to rods in the form of closed tubes. The sensor electronics are hermetically sealed and fully protected from mechanical damage and corrosion.
The sensor rod can be shortened on-site by up to 20% of its original length to match the tank depth. Rods of two standard lengths fit most fuel tanks: 800 mm, which can be shortened to 150 mm, and 1600 mm, which can be shortened to 300 mm. The maximum possible rod length is 2400 mm.
ATTENTION, currently the device is discontinued.
- Specifications
- Overall dimensions drawing
- Connection diagram
- Applications
| Construction | |
| Measuring section | Cylindrical capacitor Ø20 mm with slot, alloy EN–AW–6063–T6 |
| Insulating seals | PTFE |
| Rod length | 800 mm / 1600 mm standard, up to 2400 mm on request |
| Electronics housing | Rigid polypropylene ,Ø65 × H25 mm, protection class IP68 |
| Lower flange | Light metal alloy, rubber gasket NBR 3 mm |
| Mounting connectors | 3 screws M4 × 40 |
| Connecting cable | 1m cable in protective plastic Ø10 mm, SuperSeal connector, 7m cable extension |
| Specification | |
| Sensitivity | > 2 units per mm, typically 15 units per mm |
| Resolution | < 0.1% of output scale, typically 0.07 mm |
| Temperature error | < 0.03%, typically ±0.01% / °C |
| Nonlinearity | typically < 1% |
| Digital integration filters | Adjustable time constant and integration coefficient, output signal change rate 15...240 mm/min |
| Digital interface | CAN 2.0B per ISO 11898, baud rate 250 kb/s, compatible with SAE J1939 |
| Analog interface | 0-10 V, configurable |
| Internal calibration | Digital calibration, calibration table up to 32 points, configurable output data type |
| Power supply | 10 - 72 VDC, protection against transient overvoltage, polarity reversal and short circuits |
| Operating conditions | from –40 to +85 °C, from 0 to 100 % relative humidity, protection class IP67 |
| Fuel types | Diesel and biodiesel fuel with flash point above +60 ° C |