Vortex Flowmeter for Steam, Liquids, and Gaseous Media — VX 570
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The VX 570 vortex flowmeter features high accuracy, built-in pressure measurement, and temperature compensation. It is used for measuring the current flow of steam, liquids, and gas:
- Measurement of saturated steam or superheated steam flow
- Measurement of liquid flow
- Measurement of gas mixture flow
- Measurement of aggressive media flow
Principle of operation of the vortex flowmeter:

Features and advantages
- Measurement of flow normalized to standard conditions, current and accumulated flow;
- Measurements at medium temperatures up to 350°C;
- Measurements at pressures up to 63 bar;
- The flowmeter is suitable for measurements in gases with unknown or changing composition, as well as in gas mixtures;
- Resistance to aggressive media: all parts of the device in contact with the medium are made of stainless steel;
- The device is not sensitive to vibrations due to their control measurement;
- No moving parts.
- Specifications
- Applications
Technical Specifications VX 570 |
|
| Measurement range: | See table below |
| Measuring medium: | Gas, gas mixture, saturated steam, superheated steam, liquids |
|
Accuracy: Flow rate (m³/h) |
Gas / Steam: ± 1 % of measured value (Re > 20,000) ± 2 % of measured value (10,000 < Re < 20,000) Liquid: ± 0.75 % of measured value (Re > 20,000) ± 2 % of measured value (10,000 < Re < 20,000) |
| Mass flow (kg/h) or flow normalized to standard conditions (n.m3 /h) |
Gas / Steam: ± 1.5 % of measured value (Re > 20,000) ± 2.5 % of measured value (10,000 < Re < 20,000) |
| Measurement principle: | Vortex flowmeter |
| Medium temperature: | -40°…+350°C |
| Operating pressure: | up to 63 bar |
| Protection degree | IP67 |
| Material in contact with medium: | Stainless steel 304 |
| Electronics housing material: | Die-cast aluminum |
| Output signals: |
Standard output signals: RS 485 (Modbus-RTU), 3 analog outputs 4...20 mA Option: Ethernet interface |
| Power supply: | 18…36 V (DC) |
| Measurement range ratio: |
Gases: 1:30 Steam: 1:35 Liquids: 1:35 |
| Viscosity |
DN 15 ≤ 4 mPa•s DN 25 ≤ 5 mPa•s DN 40...DN 300 ≤ 7 mPa•s |
| Repeatability: | ± 0.3 % of measured value |
| Pipeline connection: |
Flange DIN EN1092-1 Flange ANSI Intermediate flange |
Measurement Ranges VX 570 (in m/s under operating conditions) |
||||||
| Diameter | Gas | Steam | Liquid | |||
| from | to | from | to | from | to | |
| DN 15 - DN 20 | 6 m/s | 60 m/s | 6 m/s | 70 m/s | 0.3 m/s | 7 m/s |
| DN 25 - DN 32 | 4 m/s | 60 m/s | 4 m/s | 70 m/s | ||
| DN 40 - DN 300 | 2 m/s | 60 m/s | 2 m/s | 70 m/s | ||