Flow meter for measuring compressor performance — VD 500

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The sensitive element is a precise differential pressure sensor that measures differential/dynamic pressure. The pressure depends on the flow velocity of the corresponding gas. Using the known pipeline diameter, it is easy to determine the flow rate of gas or compressed air. Thanks to additional measurements of temperature and absolute pressure, as well as the calculation of the corresponding density, measurements of various gases can be carried out over wide temperature and pressure ranges.

Advantages

  • New capability: unique sensitivity in the lower measurement range - flow measurement from 2 m/s, covering the entire operating range of variable speed drive (VSD) compressors.
  • Ideal for measuring extremely high flow rates
  • Measured parameters: flow, total consumption, temperature, and pressure.
  • Operation at high temperatures: maximum medium temperature: 180 °C.
  • Application range: can be used in pipelines from DN 20 to DN 600.
  • Pressure installation using a 1/2" ball valve
  • Specifications
  • Overall Drawing
  • Connection diagram
  • Applications

Specifications
Measurement range 2–224 nm/s / up to 600 nm/s (for compressed air) 0.04 to 500 mbar differential gas pressure
Measuring medium Air, non-aggressive gases
Accuracy ± 1.5 % of measured value
Measurement principle Differential pressure
Measurement limit 1:100
Response time t 99: < 1 s
Medium temperature -30°...+180° C
Operating pressure 1...+30 bar
Ambient temperature 20 °…+70 °C
Power supply 18…36 (V) DC, 5 W
Output signals Standard: RS 485 (Modbus-RTU), 4...20 mA pulse output. Optional: Ethernet (PoE), M-Bus, IO-Link

Electrical connection

Connector A  Connector B 
Pin number Pin color Function
(Connector A)
Function
(Connector B)
Pin 1 brown +VB NC
Pin 2 white RS 485 (A) GND
Pin 3 blue -VB DIR
Pin 4 black RS 485 (B) Pulse
(galvanically isolated)
Pin 5 gray I+
4..20 mA
Pulse
(galvanically isolated)
Designation Comment
-VB Power supply negative 0 V
+VB Power supply positive 12...30 VDC
I + Current signal 4..20 mA – selected measurement
RS 485 (A) Modbus RTU A
Pulse Pulse output for accumulated flow
NC Do not connect to voltage and/or ground. Cut and insulate the contacts
RS 485 (B) Modbus RTU B