Flow Direction Relay — VA 409
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The VA 409 flow relay is used to determine the direction of compressed air and gas flow, especially in looped pipelines.
The VA 409 helps to easily and quickly determine the direction of compressed air flow. Unlike previously used mechanical vane flow relays, the VA 409 quickly detects even minor changes in gas flow direction without any mechanical movements.
Information about the flow direction is transmitted via a potential-free contact (normally closed, max. 60 VDC, 0.5 A) to the VA400/VA420 flow sensor or to an external dispatch system. The direction indication is provided by two LEDs.
When combined into a system with two VA400/VA420 sensors, the device allows for accurate measurement of incoming and outgoing air in looped pipelines.
Advantages
- Detects the slightest changes <0.1 nm/s;
- No moving parts;
- Simple installation under pressure.
- Specifications
- Overall Drawing
- Connection diagram
- Applications
| Technical Specifications VA 409 | |
| Direction detection range | < 0.1 m/s at 20°C and 1000 mbar |
| Measurement principle | Calorimetric |
| Sensing element | Pt 30/ Pt 700/ Pt 330 |
| Measuring medium | air, other gases |
| Operating temperature | probe: 0...50°C housing: -20...70°C |
| Operating pressure | up to 16 bar |
| Power supply | 24 VDC, 40 mA |
| Power consumption | max. 80 mA up to 24 VDC |
| Protection class | IP 54 |
| EMC | according to DIN EN 61326 |
| Electrical connection | 2 x M12, 5-pin connectors A and B |
| 2 potential-free contacts | 2 x U max. 60 VDC, I max. 0.5 A (normally closed); on request: normally open |
| Housing material | Polycarbonate |
| Probe material | material: stainless steel 1.4301, dimensions: 160 mm, Ø 10 mm, sealing ring Ø11.5 mm, other lengths on request |
| Process connection | G 1/2“ |
| Housing diameter | 65 mm |
| Display | 2 LEDs |

|
Connector |
Contact Number |
Contact Color |
Designation (Connector A) |
Designation (Connector B) |
![]() |
Contact 1 | brown | GND -VB 0 V |
NC |
| Contact 2 | white | Contacts open when flow direction is left to right | Contacts open when flow direction is right to left | |
| Contact 3 | blue | |||
| Contact 4 | black | NC | NC | |
| Contact 5 | gray | +24 VDC +VB |
NC |
| Designation | Comment |
| GND, -VB | Power negative 0 V |
| +VB | Power positive 12...30 VDC |
| Contact 2 Contact 3 |
Normally open contact, opens ≤ 0.1 m/s, max. 60 VDC, 0.5 A |
| NC | Not connected |
You may find useful




-min.jpg)