Electromagnetic Flowmeter — QTLD
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
Electromagnetic flowmeter — one of the most common types of flowmeters. Flanged electromagnetic flowmeters have been used in various industries for over 50 years and are suitable for any conductive liquids such as water, acids, alkalis, milk, suspensions, etc.
The advantages of electromagnetic flowmeters lie in the absence of moving parts, pressure retention, and minimal maintenance. Flanged magnetic flowmeters are available in a wide range of sizes from DN3 to DN3000 mm and provide bidirectional flow measurement.
The QTLD flowmeter is equipped with a built-in self-diagnosis function, data recording via Bluetooth, and various types of output signals.
The limitation of the electromagnetic flowmeter compared to other types of flowmeters is that it only works with conductive liquids. It is not suitable for non-conductive liquids such as petroleum products and organic solvents. Also, the electromagnetic flowmeter is sensitive to strong magnetic fields in the environment.
The electromagnetic flowmeter is used in various industries, including water treatment, food industry, pharmaceuticals, petrochemicals, paper industry, chemical monitoring, and others. In metallurgy, it is used to control the flow of cooling water during continuous steel casting, steel rolling, and in steel melting electric furnaces. In the water supply and sewage sector, electromagnetic flowmeters are often used to measure water supply, including finished products and raw water, at water treatment plants.
- Specifications
- Overall dimensions drawing
- Applications
Specifications |
|
| Measuring diameter | DN3-DN3000mm (1/8"-120") |
| Limit of basic relative error | ±0.5% of measured value at velocity ≥ 0.5m/s, ±0.2% (optional) of measured value at velocity ≥ 0.5m/s |
| Measured medium velocity | 0.1~15 m/s |
| Measurement result reproducibility | ≤0.17% |
| Design type | Compact / Remote version (cable length 10m standard, 100m maximum) |
| Conductivity of measured medium | >5 μS/cm |
| Dust and water protection rating | Transmitter: IP65 standard, IP67 optional Sensor: Standard IP65, IP68 (submersible, available only for remote version) |
| Electrode material | SS316L, Hastelloy, Titanium, Tantalum, Platinum-iridium, Tungsten carbide |
| Power supply | 85~250 V AC (50/60 Hz), 20~36 V DC, 9~36 V DC from solar cell |
| Power consumption | <20W |
| Output analog signal | Analog: 4~20mA (load 0~750Ω) Alarm signal: Two isolated open collectors are used to output alarm signals. Frequency signal: Forward and reverse flow output with frequency range 1~5000 Hz |
| Output digital signal | RS485 MODBUS RTU by default, HART, GPRS, PROFIBUS (optional) |
| Display | LCD display, 128X128 mm, three lines, 4 buttons (optical) |
| Ambient temperature | -20°C~60°C |
| Measured medium temperature | Compact: -20°C~80°C Remote version: -20°C~120°C |
| Lining material | PTFE (-20°C~150°C, DN15-DN1600) FEP (-20°C~120°C, DN3-DN1800) PFA (-20°C~160°C, DN3-DN800) Polyurethane (-10°C~60°C, DN40-DN1600) Neoprene (-10°C~80°C, DN40-DN3000) Hard rubber (-10°C~80°C, DN 40-DN3000) Ceramics (-20°C~180°C, DN15-DN200) |
| Flange connection standard | DIN, ANSI, JIS |
| Sensor housing material | Measuring system: SS304 Flange and housing: carbon steel (standard), SS304 / SS316 optional |
| Transmitter housing material | Aluminum alloy with epoxy coating |
| Nominal flange connection pressure | PN10 / PN16 / PN25 / PN40 DIN 10K / 20K / 30 K JIS 150# / 300# / 600# ANSI High pressure up to 42 MPa / ANSI 2500# can be made to order |
| Display information | Instantaneous flow, total flow, flow velocity |
| Diagnostic functions | High and low level alarm, alarm signal, empty pipe alarm, self-diagnosis |
| Types of totalizing counters | Three built-in summing devices: forward flow, reverse flow, and net flow |
| Display units | L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h |
| Menu language | English, Italian, Portuguese, French, Spanish |