Description
A small and easy-to-install differential pressure sensor allows testing the quality of filters in compressed air systems by measuring the differential pressure before and after the filter, thereby determining the degree of its contamination. This helps to consistently maintain proper compressed air quality. The sensor is housed in a miniature case equipped with a mounting plate for attaching the device.
Advantages
- Minimization of pressure drop (energy loss)
- Allows filter replacement based on the differential pressure value specified by the manufacturer, rather than on the service life (except for carbon filters). This enables optimal filter performance over a long period.
- Specifications
- Applications
Specifications |
|
| Measurement range | 0 ... 1.6 bar differential pressure |
| Max. system pressure | 10 bar |
| Max. overload on both sides | 15 bar |
| Max. overload on one side | positive side: 15 bar negative side: 10 bar |
| Burst pressure | 60 bar |
| Accuracy | 2.0% FSO |
| Output signal | 4 ... 20 mA (2-wire) |
| Power supply | 10 ... 30 VDC; output 4...20 mA |
| Ambient temperature | -20 ... +80 °C |
| Process connection | 2× internal thread G1/8 with connector for 6 mm tubing |
| Electrical connection | Connector M12 × 1 |