Multifunctional Pressure Calibrator — LPC 100

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The multifunctional LR-Cal LPC 100 pressure calibrator is designed for measuring pressure (using an external reference pressure sensor Keller 33X) and working with instruments that use a current loop. The calibrator can also measure DC voltage and circuit continuity.

  • Measures pressure, current (milliamps), voltage, and circuit continuity
  • Easily connectable interchangeable reference instrument LR-Cal LPC-1
  • Milliamp power supply
  • Two displays simultaneously show input and output values
  • Power supply for transmitters 24 V and analog signal acquisition (4...20 mA)
  • Choice between stepwise and linearly increasing function
  • Data storage on included SD card
  • USB interface
  • Replaceable ion-lithium battery with mains charger
  • Graphical display of results

Ability to easily change reference pressure sensors. Simultaneous measurement of pressure and current is an ideal solution for calibration.

A special measurement function allows precise and safe calibration of pressure switches.

The LR-Cal LPC 100 recording function allows saving data on the supplied SD card and later transferring it to a PC in the most common spreadsheet formats using the built-in USB port.

Compact size, ion-lithium battery, and high accuracy make the LR-Cal LPC 100 an ideal tool for use in the manufacturing sector.

  • Specifications
  • Applications
Measured Parameter Range Accuracy Resolution
Pressure Depends on the sensor type 33X or 41X (see separate table)
Current mA 0...24 mA (impedance ±17 Ohm) 0.005% FSO ±1 digit 1µA
Voltage mV -10…+100 mV (>1MOhm) 0.01% FSO ±1 digit 1 µV
Continuity With 100 Ohm trigger. Visual and audio confirmation

 

Specification Value
Insulation Max. 100 VDC between all inputs and outputs
Power Supply Type: replaceable ion-lithium battery
Charging time: about 5 hours
Operating time: average – 8 hours (depends on used functions)
Charging from mains Input voltage to calibrator: 10…15 VDC
Input voltage: 115…230 VAC; 0.5 A; 50/60 Hz
Output voltage: 12 VDC at 1.5 A
Car charger (optional): 12 VDC at 1 A via cigarette lighter
Temperature ranges Storage: -40…+60°C, including battery
Operating: 0…50°C
Relative humidity 0…85% RH (non-condensing)
Housing ABS plastic, IP54 dust and splash protection, UL94V-0 flame retardant
Rubber case Green
Dimensions Without rubber case: 149 x 34 x 77 mm
With rubber case: 155 x 43 x 86 mm
Weight About 340 g.
Included in basic delivery LR-Cal LPC 100 pressure calibrator with rubber case
SD memory card
Set of test probes (1 x red; 1 x black)
Charger 115…230 VAC
Plastic case
User manual (German/English)
Factory calibration certificate
Warranty 24 months from delivery date