Oxygen sensor — AO-09

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

AO-09 is an electrochemical oxygen sensor designed to measure oxygen concentration, specifically developed for medical equipment.

The sensor has a molded housing, provides a fast response, and has a long service life.

Features

  • Linear output
  • No external power supply required
  • Temperature compensation
  • Fast response
  • Accurate and reliable
  • Interference protection

Applications

When using the AO-09, no external power supply is required. Sensors are calibrated before leaving the factory. The sensors feature temperature compensation to avoid temperature effects.

The AO-09 sensor can be used as a sensitive element in an oxygen analyzer or as a control component in an oxygen generator, as well as in medical ventilators, anesthetic equipment, and incubators.

WARNING, the device is currently discontinued.

  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications

Specifications

Operating principle Electrochemical partial pressure
Output voltage 9 ~ 13 mV (in ambient air)
Measurement range 0 ~ 100%
Response time (T90) < 15 s
Accuracy ± 1%
Linearity Linear from 0% to 100% O2
Temperature compensation < 2% O2 (0 ~ 40 °C)
External load resistor ≥ 10 kOhm
Connector 3P 2.54
Housing material White ABS
Weight 40 g
Operating temperature range 0 ~ 50 °C
Operating pressure range 0.5 ~ 2.0 bar
Operating humidity range 0 ~ 99% relative humidity (non-condensing)
Long-term output drift at 100% O2 (voltage loss/year) < 5%
Expected service life 1.5 x 106 % O2 hours (20°C)
0.8 x 106 % O2 hours (40°C)
Shelf life 13 months from shipping date

Overall dimensions of AO-09 (unit of measurement: mm, tolerance: ± 0.15 mm)

AO-09 dimensions

AO-09 diagram