Methane detector-transducer with two relay outputs — E2611-CH4

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The E2611-CH4 methane detector is a representative of the new line of multifunctional measuring instruments PluraSens®.

The detector can be used in kitchens equipped with gas stoves, boiler rooms, and other premises where potentially explosive concentrations of methane may accumulate.

By default, the alarm triggers at 20% LEL and 50% LEL of methane. The user can also set other threshold concentration values.

Thanks to two relays with normally open contacts, the detector can be used for remote notification and control. An audible alarm also sounds when threshold concentrations are reached.

The detector is equipped with a fully calibrated latest-generation metal oxide sensor with temperature compensation, ensuring high stability and reliability of readings, as well as a long service life of the device.

To connect the detector to ventilation, security, and building automation systems, two configurable analog outputs and an RS485 interface operating via the Modbus RTU protocol can be used.

  • Specifications
  • Connection
  • Overall dimensions drawing
  • Applications
Specifications
Calibration methane CH4
Sensor type metal oxide semiconductor
  pellistor on request
Sampling method diffusion
Detection range 0...100% LEL (0...5 vol. %) CH4
Resolution 0.1 %LEL (50 ppm) CH4
Accuracy ± 5 %LEL (± 0.25 vol. %) CH4
Sensor lifespan > 10 years
Power supply 11...30 V DC or 90...265 V AC
Digital interface RS485, Modbus RTU protocol
Alarm 85 dB sound signal
Analog outputs 2 × 4-20 mA / 0-10 V, configurable
Output relays 2 single-pole relays (normally open contact),
  250 V AC / 30 V DC, up to 5 A
Default alarm trigger threshold  20 %LEL / 50 %LEL
Enclosure ABS plastic with ventilation slots,
  wall mounting, protection class IP20
Dimensions H85 × W85 × D37 mm
Operating conditions -30...+70 °C, 0...95 %RH, non-condensing