CO2 Carbon Dioxide Level Sensor — iMK stock

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

Wall-mounted converter with built-in CO2 concentration, temperature, and relative humidity sensor for installation in greenhouses, incubators, mushroom farms, and similar environments.

Multipoint CO2 and temperature calibration procedure ensures excellent CO2 measurement accuracy across the entire operating temperature range; this is essential for process control and outdoor applications. The CO2 detection procedure using an NDIR infrared sensor automatically compensates for aging effects using the ABC algorithm.

The CO2 module is highly resistant to contamination, requires no maintenance, and provides long-term stability.

  • Specifications
  • Overall dimensions drawing
  • Applications

CO2 Sensor

 
Sensitive Element Non-dispersive Infrared Detector (NDIR)
Measurement Range 0~2000ppm / 0~5000ppm (option)
Accuracy ±40ppm + 3% of measured value
Temperature Dependence 0.2% full scale per °C
Stability <2% over sensor lifetime >15 years
Pressure Dependence 0.13% reading per mm Hg
Calibration ABC self-calibration algorithm
Response Time <2 min.
Signal Update every 2 sec.
Warm-up Time 2 hrs (first time) / 2 min (operation)
 

t

RH

Measurement Range 0°C~50°C 0 ~100%RH
Accuracy ±0.4°C (20°C~40°C) ±3%RH (20%-80%RH)
Display Resolution 0.1°C 0.1%RH
Stability <0.04°C/year <0.5% RH/year

General Specifications

Power Supply 24 VAC/VDC
Power Consumption 1.8 W max.; 1.2 W average
Analog Outputs 1-3 x analog outputs
0~10VDC (default) or 4~20mA (jumper selectable)
0~5VDC (option)
Modbus digital RS485 Modbus RTU interface
Operating Range 0~50°C; 0~95%RH, non-condensing
Storage Conditions 0~60°C, 5~95%RH, non-condensing
Weight 300 g
Dimensions 169×124×50 mm HxWxD
Mounting wall-mounted
Protection Rating IP50

iMK stock

Send request

Request a callback

Information sent successfully

Благодарим за обращение.
Ваша заявка будет рассмотрена в рабочее время:
Пн-Пт с 9 до 18 по московскому времени.