CO2 concentration converter with two relay outputs and remote probe. — H5021

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

CO2 concentration converter with a remote probe of various lengths (1, 2, 4m). Equipped with two relay outputs for alarm indication or control of external devices. For each relay, delay settings, hysteresis, and sound signal are included. Parameters are easily adjustable using a computer or the control buttons on the device. The sensor is controlled by a microprocessor housed in a durable plastic case with connection terminals. A large two-line  LCD  display is designed to simultaneously show two parameters. The display can be turned off if necessary.

Recently, the level of carbon dioxide is considered one of the most important parameters responsible for indoor climate quality. Especially in buildings and rooms with large gatherings of people, such as conference halls, hospitals, schools, cinemas, theaters, and wellness centers.

With the help of CO2 sensors, engineers, environmental experts, and healthcare specialists can optimize ventilation to create a comfortable and «Healthy» indoor climate.

ATTENTION, the device is currently discontinued.

  • Specifications
  • Overall Drawing
  • Electrical diagram
  • Applications

Sensor

H5021

Power supply voltage / power consumption during normal operation / max. power consumption

9 – 30Vdc / 1W / 4W

Relay outputs - max. voltage / max. current / max. power

50V / 2A / 60VA

CO2 concentration measurement range

from 0 to 10000 ppm

CO2 concentration measurement accuracy at 25оC and 1013 hPa

± (100ppm + 5% of measured value)

Additional temperature error from 0 to 500C

2 ppm CO2/°C

Recommended calibration interval

5 years

Sensor protection class with built-in sensor / with external CO2 probe

IP65 / IP65

Operating temperature range of sensor with built-in sensor

from -30 to +80°C

Operating temperature range of sensor with external CO2 probe

from -40 to +60°C

Operating humidity range (without condensation)

from 0 to 100% RH

Operating pressure range

from 850 to 1100 hPa

Number of relay outputs

2

Resolution

1 ppm

Sensor position during installation

Any position

Storage temperature range (from 5 to 95% RH, without condensation, atmospheric pressure from 700 to 1100 hPa)

From – 40 to + 60°C

Electromagnetic compatibility

EN 61326-1, EN 55011

Weight without probe / with 1m / 2m / 4m probe

330/420/450/510

Warranty

3 years

SP003 cable for configuring the controller parameters via USB port does not power the sensor. Power must be supplied from an external source through the +U and GND terminals

Connecting the relay to the sensor outputs

Send request

Request a callback