CO2 Concentration Converter with Analog Outputs — eSENSE Disp

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

eSENSE™ – a simple and inexpensive CO2 content converter that does not require periodic maintenance and is designed for installation in climate zones and ventilation shafts. It allows cost savings by reducing energy consumption and helps create a more favorable indoor environment. Measures CO2 content in the surrounding air up to 10000 ppm and transmits data via analog output. Outputs 0-10 V DC and 4-20mA DC or 2-10 V DC and 0-10 V DC

Advantages

  • No maintenance required
  • Various CO2 measurement ranges and different housing options available
  • Automatic self-diagnosis
  • 5-year warranty

ATTENTION, the device is currently discontinued.

  • Specifications
  • Overall dimensions
  • Connection
  • Applications

Sensor

eSENSE Disp

Measured gas

Carbon dioxide CO2

Measurement range

0 – 2000 ppm (optional 5000, 10000 ppm)

Accuracy

± 30 ppm ±3% of measured value

Dimensions

100 mm x 80 mm x 28 mm

Maintenance

No maintenance required*

Service life

˃ 15 years

Temperature compensation range

From 0 to 50 °C

Operating humidity range

From 0 to 95% RH (no condensation)

Power supply

24 VAC/VDC

Response time (T1/e)

2 min.

Data transmission

Uart (Modbus)

Output #1 linear output

From 0 to 10 V DC (CO2)

Output #2 linear output

From 2 to 10 V DC or from 4 to 20 mA (CO2)

 

Attention!

The same grounding scheme must be used for the control system and the sensor

 

Output

Purpose

Electrical

Characteristics

Comment (Default settings)

Terminal +

 

Terminal ┴

Power (+)

 

Power

Ground (-)

24 VAC/DC +

(±20%), 2W

 

24 VAC/DC -

 

 

 

Output (1)

Analog output 1 (+)

0 – 10 VDC

0 – 2000 ppm

Output (2)

Analog output 2 (+)

2.0 – 10.0 VDC or

4.0 – 20.0 mA

0 – 2000 ppm

0.9 – 1.6 VDC or

1.5 – 2.5 mA

Status = ERROR

0 VDC or 0 mA

Status = NOT READY

 

 

 

    Send request

    Request a callback

    Information sent successfully

    Благодарим за обращение.
    Ваша заявка будет рассмотрена в рабочее время: